1
1.
PRECAUTIONS AND NOTICES
1.1
SAFETY PRECAUTIONS
1) Observe all cautions and safety related notes located inside the display cabinet and on the
displaychassis.
2) Operation of this display outside the cabinet or with the cover removed, involves at shock
harzard from the display power supplies. Work on the display should not be attempted by anyone
who is not thoroughly familiar with precautions necessary when working on high voltage
equipement.
3) Do not install, remove or handle the picture tube in any manner unless shatter-proof goggles
are worn. People not so equiped should be kept away while handling picture tube.Keep picture
tube away from body while handling.
1.2 Observe all cautionary and safety related notes located on the chassis, cabinet and display tube.
1.3 Operation of the monitor with the back cover removed presents a potential shock hazard. Only
personnel familiar with the precautions necessary for safe working on high voltage equipment
should attempt to carry out servicing.
1.4
Always wear shatter proof goggles when removing, installing or generally handing the picture tube.
People not so equipped should be kept at a safe distance when any such handing is being
undertaken. Do not handle the picture tube by the neck of deflection coil. Do not carry the picture
tube resting against the body.
1.5
The picture tube is designed and constructed to limit X-Radiation to a safe level during normal
operation. To maintain the required level of protection and safe operation, replacement tubes
must be correctly adjusted and any protective circuits must not defeat.
1.6
IMPORTANT-Safety Tests
After servicing, and before returning the monitor to the user, a thorough safety test must be
carried out to ensure there is no potential shock hazard to any operator(s) using the monitor.
All the following test must be performed. A monitor failing any of these tests should be rejected
and have the problem rectified.
1.7
A.C. Leakage Test
Remove the power sourse. Connent the monitor to the circuir as in figure 1 below. Switch the
monitor on/off switch to on. A reading of less than 3.5mA should obtained (ref. EN60950).
Equipment safety
Earth terminal
Equipment
Under test
Measuring instrument
Isolating
transformer
L
N
Fig.1 Measurement of AC Leakage Current.