ViewSonic CDP4260-TL User's Guide Page 46

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 45
38
Get function table:
Get Function Length ID Command
Type
Command Value Range Comments
Code (ASCII) Code (Hex) (Three ASCII bytes)
Get-Contrast 8 g a 61 000 ~ 100 Gets Contrast value
Get-Brightness 8 g b 62 000 ~ 100 Gets Brightness value
Get-Sharpness 8 g c 63 000 ~ 100 Gets Sharpness value
Get-Color 8 g d 64 000 ~ 100 Gets Color value
Get-Tint 8 g e 65 000 ~ 100 Gets Tint value
Get-Volume 8 g f 66 000 ~ 100 Gets Volume value
Get-Mute 8 g g 67 000: OFF (unmuted)
001: ON (muted)
Gets Mute ON/OFF
status
Get-Input select 8 g j 6A 000~ See Set-function table
Get-Power
status : ON/
STBY
8 g l 6C 000: STBY
001: ON
Get-Remote
control
8 g n 6E 000 : Disable
001 : Enable
002 : Pass through
Get-Power Lock 8 g o 6F 000 : Unlock
001 : Lock
Get-Button Lock 8 g p 70 000 : Unlock
001 : Lock
Get-Menu Lock 8 g q 71 000 : Unlock
001 : Lock
Get-PIP Mode 8 g t 74 000 : OFF
001 : PIP
002 : PBP
Get-PIP Input 8 g u 75 000~ See Set-function table
Get-Tiling Mode 8 g v 76 000 : OFF
001 : ON
Get-Tiling
Compensation
8 g w 77 000 : OFF
001 : ON
Get-Tiling H by V
monitors
8 g x 78 01x~09x: H monitors
0x1~0x9 : V monitors
1. 2nd digital for H
monitors
2. 3rd digital for V
monitors
Get-Tiling
Position
8 g y 79 000 : OFF
001~025
Get-ACK 8 g z 7A 000 This command is
used to test the
communication link.
Page view 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 52

Comments to this Manuals