ViewSonic Corporation Confidential - Do Not Copy Q7b-3
24
5. Adjustment Procedure
1. Function test
1.1 products
17” LCD Monitor
1.2 test equipment
(2-1). One PC (Windows system);two RS-232 PORT,COM1: signal resolution、COM2: color
meter。
Print PORT: connection with IIC/RS-232 Adapter Board
(2-2).Color Meter: MINOLTA. CA-110 is 21cm apart form the screen (eg: BM-7 distance is 50cm;
Field = 2.0)
(2-3). IIC/RS-232 Adapter Board (Set IIC Port)
(2-4). (TOPCON BM-7 or CA110) will be upright with Monitor
(2-5).each equipment’ s connection circuit diagram, pls see the appendix two and three.
(3).Setup
( 3-1 ).with 32 level gray scale Pattern
(3- 2 ).Brightness Set 50; Contrast Set 50.
( 3-3 ). Auto White Balance:
Entered into Maintain mode then choose Menu (F199N) Icon ,and press (+) Key to enter
into Maintain Menu; choose Auto Color ,press down (+) Key to implement Auto Color
Adjust。
(4).adjust specification:
At Brightness=50, Contrast=50 Full White Pattern
6500°K: x=0.313±0.015;y=0.329±0.015
9300°K: x=0.283±0.015;y=0.297±0.015
S RGBK : x=0.313±0.015;y=0.329±0.015
Brightness=50,Contrast=50 Full White 180 CD/M≧
2
(5). Applicable program exercitation (use the color temperature adjust program to adjust color
temperature)
MINOLTA CA-110
Comments to this Manuals